Antenna Trap Calculator

LC & coaxial traps · Nagaoka / Rosa · STL export

LC sizing, coil former calculation (Nagaoka / Rosa) and STL export for 3D printing — for multiband trapped antennas.

1. Trap LC Calculator

Trap Type
Calculate
MHz
µH

Result
— pF
Recalculated F₀
—
Reactance at F₀
—

Formula: f = 1 / (2π√(LC)). Theoretical estimate — validate/adjust in practice with an LCR meter and SWR meter.

Trap Power Rating

W

V eff.

%

η depends on the antenna and on how far f₀ is from the operating frequency: it cannot be computed here. The reference values come from W8JI's published EZNEC analyses (total loss of both traps in a trapped dipole).

CW
—
Max. PEP power — CW (40 % duty cycle)
FT8
—
Max. PEP power — digital / FM (100 %)
SSB
—
Max. PEP power — SSB (20 %)
▶ Second case: trap used as a loading coil on a lower band
MHz
Ω

Below its resonance the trap is no longer a rejector but a loading coil carrying the antenna current, amplified by 1/(1−(f/f₀)²) inside the coil. The current through it is bounded by the feed-point current √(P/R); factor k scales it to the trap's actual position (k = 1: worst case, trap at the current maximum). In practice the trap sits further out along the element and k is well below 1: cross-checking against the 0.05 dB loss W8JI publishes on 80 m puts k around 0.35–0.45, but that figure depends on the exact geometry and on assumptions about X and Q — determine it by NEC modelling. Q is assumed constant with frequency (it actually rises roughly as √f). The power shown assumes a 100 % duty cycle.

Reading the result: all three figures are PEP powers, set by whichever of the two mechanisms binds first: the voltage across the trap (envelope peak, mode-independent) and, for a discrete coil, wire heating (an average value, hence duty-cycle dependent). They rest entirely on η above: doubling η halves the admissible power. If the trap is coaxial and no maximum voltage is entered, no limit can be computed and the boxes stay empty.
Why transmitter power alone is not enough. What constrains a trap is the voltage across it and the current through it, not the transmitter's output. Both follow from the power actually dissipated in the trap — a fraction η of the transmitted power that depends on the antenna: W8JI's modelling gives 1.6 dB total loss for both traps in the worst case (a coaxial trap working at its resonance) and 0.24 dB for a discrete-coil trap. For a coaxial trap the limit used here is the cable's voltage withstand (MIL-DTL-17: RG-58/58C 1900 V rms, RG-174 1500 V rms, RG-213/214 5000 V rms); no thermal limit is offered, since the braid and centre-conductor cross-sections are not in the cable list. For a discrete coil the limit is the lower of wire heating and the capacitor voltage — and the capacitor must also handle the circulating current shown.

Model, at resonance: Rp = Q·XL, Vrms = √(Rp × η × PPEP), I = Vrms/XL. Limits: PPEP = Vmax²/(Rp × η) for voltage, PPEP = Imax² × XL/(Q × η × d) for heating, with Imax = 3.5 A/mm² of copper (enamelled wire in free air, usual range 2.5–6) and d the average-to-PEP duty cycle: 40 % CW, 20 % SSB without processing (40 % with heavy processing), 100 % digital and FM — ARRL "RF Exposure and You", worksheet B.

2. Former Sizing (Nagaoka / Rosa)

µH
mm
mm
Wheeler Recalculated inductance: — µH
Number of Turns (N)
—
Winding Length
—
Turn Pitch
—
Wire / Cable Length
—

Formule de Wheeler : L(µH) = (D² × N²) / (18D + 40ℓ), D et ℓ en pouces. Calcul itératif sur N. Theoretical estimate — manufacturing tolerance ±5–10%, final adjustment with LCR meter.

3. STL Export for 3D Printing

mm
mm

Print workflow: generate the preview to check the geometry, then download the .stl file and open it directly in your slicer — PrusaSlicer, Cura, OrcaSlicer, etc. No intermediate conversion required.

Recommended material: PETG for a trap intended for permanent outdoor use (better UV and heat resistance). PLA is acceptable for portable use or a temporary test prototype, but deforms under direct sunlight.

The parametric former is generated directly in the browser (triangulated mesh, no external dependency). The guide groove is obtained by local radial deformation of the tube along a true helical path, sized to the effective diameter entered in module 2 — winding wire in discrete coil mode, or the outer diameter of the selected coaxial cable (synchronised automatically) in coaxial trap mode. Pitch and groove depth adjust accordingly; adjust for your printer's tolerance.

4. Assembly Diagram

The diagram updates automatically with the calculated parameters.