RF Unit Converter – HB9HIT

RF Unit Converter

RF Unit Converter · hb9hit.com

Unit converters and calculators for radio and electronics. Choose a conversion or a calculator: each page explains what is calculated and gives the formulas, the assumptions and a worked example.

Quick conversion

Calculators

RF & frequencies 15

Antennas & propagation 8

Lines & matching 21

Signals, filters & modulation 11

Noise & reception 12

Electronics 42

Power & thermal 15

Mechanics: masts, rotators, wires 12

RF conversion guide for radio amateurs

This RF unit converter brings together the conversions used every day in the shack and the lab: power in watts and dBm, antenna voltage in µV and dBµV, SWR and return loss, gain in dBi and dBd, wavelength, electric field in V/m or dBµV/m, noise figure and S-meter. Everything is computed in your browser; no data is sent.

A logarithmic unit only makes sense with its reference: dBm refers to 1 mW, dBW to 1 W, dBµV to 1 µV. Going from power to voltage requires an impedance: the tables below are computed for 50 Ω, the standard for amateur receivers and cables.

The converters cover 43 families of quantities useful in radio: in each one, type a value in any row and every unit updates. Conversions that depend on a parameter (impedance for dBm ↔ µV, velocity factor for λ, nominal voltage for Wh) show it above the results.

The unit mixer evaluates expressions mixing units (feet and centimetres, dBm and mW, V and A…) with dimension checking, then converts to the unit of your choice.

The calculators handle cases that are not simple conversions: link budget, received field, SWR, complex impedance, coaxial line, noise, Doppler, locator… Each page details the formulas, the assumptions and a worked example.

Three kinds of conversion

  • Exact conversion Plain change of unit: the result depends on no material, component or context.
  • Depends on a parameter The result depends on an extra quantity (impedance, voltage, frequency…) entered under “Parameters”.
  • Valid under an assumption The result is only right under the stated assumption (sine wave, far field, equal impedance…).

dBm ↔ watts ↔ µV table (50 Ω)

From receiver sensitivity (−130 dBm) to amplifier output (+60 dBm = 1 kW). Voltage is the RMS value across a 50 Ω load.

dBmPowerdBWVoltage (50 Ω)dBµV
−150 dBm1 aW−1807.07 nV−43.01
−140 dBm10 aW−17022.4 nV−33.01
−130 dBm100 aW−16070.7 nV−23.01
−127 dBm200 aW−15799.9 nV−20.01
−121 dBm794 aW−151199 nV−14.01
−110 dBm10 fW−140707 nV−3.01
−100 dBm100 fW−1302.24 µV6.99
−93 dBm501 fW−1235.01 µV13.99
−90 dBm1 pW−1207.07 µV16.99
−80 dBm10 pW−11022.4 µV26.99
−73 dBm50.1 pW−10350.1 µV33.99
−60 dBm1 nW−90224 µV46.99
−50 dBm10 nW−80707 µV56.99
−40 dBm100 nW−702.24 mV66.99
−30 dBm1 µW−607.07 mV76.99
−20 dBm10 µW−5022.4 mV86.99
−10 dBm100 µW−4070.7 mV96.99
0 dBm1 mW−30224 mV106.99
10 dBm10 mW−20707 mV116.99
20 dBm100 mW−102.24 V126.99
30 dBm1 W07.07 V136.99
33 dBm2 W39.99 V139.99
37 dBm5.01 W715.8 V143.99
40 dBm10 W1022.4 V146.99
43 dBm20 W1331.6 V149.99
47 dBm50.1 W1750.1 V153.99
50 dBm100 W2070.7 V156.99
53 dBm200 W2399.9 V159.99
57 dBm501 W27158 V163.99
60 dBm1 kW30224 V166.99

S-meter scale: HF and VHF use different references

IARU Region 1 Technical Recommendation R.1 (Brighton 1981, Torremolinos 1990) sets 6 dB per S unit into 50 Ω. Below 30 MHz, S9 is −73 dBm (50.1 µV); above 30 MHz, −93 dBm (5.01 µV), i.e. 20 dB lower. The 1990 amendment reconfirmed −93 dBm above 144 MHz without stating anything between 30 and 144 MHz (6 m, 4 m). The same signal therefore reads differently depending on the range. Many transceivers are not calibrated to R.1: the table gives the standard value, not your radio’s.

ReadingHF dBmHF µVVHF/UHF dBmVHF/UHF µV
S1−1210.199−1410.0199
S2−1150.398−1350.0398
S3−1090.793−1290.0793
S4−1031.58−1230.158
S5−973.16−1170.316
S6−916.3−1110.63
S7−8512.6−1051.26
S8−7925.1−992.51
S9−7350.1−935.01
S9 +10 dB−63158−8315.8
S9 +20 dB−53501−7350.1
S9 +30 dB−431,583−63158
S9 +40 dB−335,006−53501
S9 +50 dB−2315,830−431,583
S9 +60 dB−1350,059−335,006

SWR ↔ return loss ↔ reflected power table

SWR measured at the antenna feed point translates into reflection coefficient |Γ|, return loss and mismatch loss. A mismatch loss of 0.51 dB (2:1 SWR) means 11 % reflected power.

SWR|Γ|Return lossReflected powerMismatch loss
1:10∞0 %0 dB
1.1:10.04826.44 dB0.23 %0.01 dB
1.2:10.09120.83 dB0.83 %0.036 dB
1.3:10.1317.69 dB1.7 %0.075 dB
1.4:10.16715.56 dB2.78 %0.122 dB
1.5:10.213.98 dB4 %0.177 dB
1.7:10.25911.73 dB6.72 %0.302 dB
2:10.3339.54 dB11.11 %0.512 dB
2.5:10.4297.36 dB18.37 %0.881 dB
3:10.56.02 dB25 %1.249 dB
4:10.64.44 dB36 %1.938 dB
5:10.6673.52 dB44.44 %2.553 dB
10:10.8181.74 dB66.94 %4.807 dB

Wavelength of the amateur bands

Theoretical free-space lengths (λ = c/f) for one frequency in each band. The physical length of a dipole is shorter: apply the shortening factor in the “Wavelength & antennas” calculator.

BandFrequencyλλ/2λ/4
2200 m0.1365 MHz2,196.3 m1,098.1 m549.1 m
630 m0.475 MHz631.1 m315.6 m157.8 m
160 m1.84 MHz162.9 m81.5 m40.7 m
80 m3.6 MHz83.28 m41.64 m20.82 m
60 m5.36 MHz55.93 m27.97 m13.98 m
40 m7.1 MHz42.22 m21.11 m10.56 m
30 m10.12 MHz29.62 m14.81 m7.41 m
20 m14.2 MHz21.11 m10.56 m5.28 m
17 m18.1 MHz16.56 m8.28 m4.14 m
15 m21.2 MHz14.14 m7.07 m3.54 m
12 m24.94 MHz12.02 m6.01 m3.01 m
10 m28.5 MHz10.52 m5.26 m2.63 m
6 m50.15 MHz5.98 m2.99 m1.49 m
2 m144.3 MHz2.08 m1.04 m0.52 m
70 cm432.2 MHz0.694 m0.347 m0.173 m
23 cm1,296.2 MHz0.231 m0.116 m0.058 m

Essential formulas

  • Power: P(dBm) = 10·log₁₀(P / 1 mW); P(dBW) = P(dBm) − 30.
  • Voltage into Z: V(dBµV) = P(dBm) + 10·log₁₀(Z) + 90, i.e. +106.99 dB into 50 Ω and +108.75 dB into 75 Ω.
  • Wavelength: λ(m) = 299.792458 / f(MHz).
  • Matching: Γ = (Z − Z₀)/(Z + Z₀); SWR = (1 + |Γ|)/(1 − |Γ|); RL = −20·log₁₀|Γ|.
  • Antennas: dBi = dBd + 2.15. Far field: E = √(EIRP · Z₀ / 4π) / d ≈ √(30 · EIRP) / d.
  • Thermal noise at 290 K: N(dBm) = −173.98 + 10·log₁₀(B) + NF.

Unit mixer

Operators + − × / ^ and parentheses; convert with “→”, “in” or “to”. Levels dBm, dBW, dBµV, dBµV/m… and °C/°F become linear quantities (10 dBm + 10 dBm = 20 mW). Constants: c, pi, Z0, mu0, eps0, kB, g0. Functions: sqrt, abs, log10, ln, exp, sin, cos, tan, db. Symbols are SI case-sensitive (mW ≠ MW).

References and constants

  • Exact SI constants (2019): c = 299 792 458 m/s, k = 1.380649 × 10⁻²³ J/K, e = 1.602176634 × 10⁻¹⁹ C. µ₀ = 1.25663706127 × 10⁻⁶ H/m (CODATA 2022).
  • Imperial units: 1 in = 25.4 mm, 1 lb = 0.45359237 kg, 1 lbf = 4.4482216152605 N (exact definitions).
  • S-meter: IARU Region 1 Technical Recommendation R.1. Noise figure: T₀ = 290 K (IEEE). AWG: ASTM B258.
  • A conversion is only exact within its assumptions: sine wave for peak/RMS, far-field plane wave for E ↔ S, resistive load for P ↔ V.

FAQ

How do I convert dBm to µV?

Choose “RF level”, set the impedance (50 Ω by default) and enter the value in dBm. Into 50 Ω, 0 dBm = 223.6 mV = 107.0 dBµV.

What is the difference between dBi and dBd?

dBi refers to the isotropic antenna, dBd to the half-wave dipole: dBi = dBd + 2.15.

How do I add two levels in dBm?

In the Mixer, type “10 dBm + 10 dBm → dBm”: powers are added in watts, result 13.01 dBm.

Why is S9 −73 dBm on HF and −93 dBm on VHF?

That is the definition in IARU Region 1 Recommendation R.1: −73 dBm (50 µV into 50 Ω) below 30 MHz and −93 dBm (5 µV) above 30 MHz, with 6 dB per S unit in both cases. The 1990 amendment only reconfirms −93 dBm above 144 MHz.

How many dBµV is 0 dBm?

Into 50 Ω, 0 dBm = 223.6 mV = 106.99 dBµV. Into 75 Ω, 0 dBm = 108.75 dBµV.

Related tools

Suggest a calculator or report an error

An idea for a calculator, a value to correct? Describe it here; the request goes straight to HB9HIT.

Your data is used only to handle the request; it is neither published nor passed on.