Real losses of a coaxial feed line, from the cited manufacturer datasheets: attenuation at your frequency, effect of SWR, power at the antenna and comparison of cables under identical conditions.

Loss calculator

Advanced parameters
%
    Calculation assumptions

    Real Z0 line. Matched loss = cable × (1 + correction) + connectors + additional losses, applied once. With SWR, total loss = 10·log[(1 − ρ²a²) / (a(1 − ρ²))], a = 10^(−A/10): exact for real Z0 and independent of electrical length. Input power is the net power fed into the line. Mismatch loss at the antenna is shown for information only: it is not added to the dissipative losses.

    Same conditions, other lengths

    Cable comparator

    All cables are evaluated at the same frequency, length, power, SWR and additional losses. Tick the cables to compare; the best one for the chosen criterion is highlighted.

    Loss by frequency

    Cables ticked in the comparator (same filters), cable-only loss for the calculation length. Click a header to sort.

    Replace one cable with another

    Total loss versus length (current conditions)
    Attenuation versus frequency (documented range, datasheet points)

    Advanced tools

    Full model (telegrapher's equations) with a complex load. |Γ| at the station does not depend on phase as long as Z0 is real; however the SWR read by a meter with a different reference (e.g. 75 Ω cable, 50 Ω SWR meter) does depend on electrical length.

    Smith chart (normalised to Z0)

    Datasheet of the selected cable

    Methodology, assumptions and limits

    Data

    Every value comes from the cited manufacturer datasheet, with URL and verification date. A missing value is shown as “not documented”. Dimensions published in inches are converted (1 in = 25.4 mm); dB/100 ft → dB/100 m: divide by 0.3048.

    Attenuation at any frequency

    Datasheet point: documented value. Between two points: linear interpolation on a log-log scale (local power law A ∝ fk), flagged as an estimate. Out of range: manufacturer formula k1·√f + k2·f if the datasheet publishes one (Times Microwave), otherwise no value, unless extrapolation is explicitly allowed in expert mode.

    Mismatched line

    For a matched loss A (dB), a = 10−A/10, ρ = |ΓL| = (SWR − 1)/(SWR + 1): Pload/Pin = a(1 − ρ²)/(1 − ρ²a²); |Γin| = ρ·a. These relations are exact for a uniform line with real Z0 and do not depend on phase. The “SWR & line” tab solves the telegrapher's equations for a complex load and any SWR meter reference.

    Measured cable and measured VF (v1.1)

    Measurement correction: k = measured loss / datasheet loss at the same frequency and length; the datasheet curve is multiplied by k (proportional assumption, flagged). With the far end open or shorted, reflection is total: one-way loss = RL/2. VF by resonance: open end, minima at L = (2n−1)·λc/4; shorted end, minima at L = n·λc/2.

    Limits

    • Z0 assumed real (approximation: at low HF frequencies the Z0 of a lossy cable becomes slightly complex).
    • “Typical” or “nominal” attenuation per manufacturer; production tolerances are not included.
    • Power ratings depend on the published conditions (ambient temperature, SWR 1, altitude); SWR and temperature reduce the power actually allowed.
    • Connectors and components are treated as matched losses in series with the cable.
    • No temperature effect on attenuation is modelled: no coefficient is documented in the included datasheets.

    Source inventory

    Calculation sheet — coaxial line

    One A4 page: parameters, results, warnings, sources and date. In the print dialog, choose “Save as PDF”.