Real losses of a coaxial feed line, from the cited manufacturer datasheets: attenuation at your frequency, effect of SWR, power at the antenna and comparison of cables under identical conditions.
Loss calculator
Calculation assumptions
Real Z0 line. Matched loss = cable × (1 + correction) + connectors + additional losses, applied once. With SWR, total loss = 10·log[(1 − ρ²a²) / (a(1 − ρ²))], a = 10^(−A/10): exact for real Z0 and independent of electrical length. Input power is the net power fed into the line. Mismatch loss at the antenna is shown for information only: it is not added to the dissipative losses.
Same conditions, other lengths
Cable comparator
All cables are evaluated at the same frequency, length, power, SWR and additional losses. Tick the cables to compare; the best one for the chosen criterion is highlighted.
Loss by frequency
Cables ticked in the comparator (same filters), cable-only loss for the calculation length. Click a header to sort.
Replace one cable with another
Advanced tools
Full model (telegrapher's equations) with a complex load. |Γ| at the station does not depend on phase as long as Z0 is real; however the SWR read by a meter with a different reference (e.g. 75 Ω cable, 50 Ω SWR meter) does depend on electrical length.
Line made of several sections (jumpers, main cable…), from transmitter to antenna. Frequency, power and antenna SWR are taken from the main calculation.
Cables saved from your measurements (measured cable in the main calculation or VNA import). They appear in the calculation, the comparator and the multi-section line under “My measured cables”.
Stored only in this browser (nothing is sent to the server). Export them to back up or use on another device. The power rating used is that of the base cable datasheet.
Enter any quantity: the others are recalculated.
Measure the frequency of an impedance minimum (minimum R, X = 0) of a section of known length, far end open or shorted, with an antenna analyser.
Import an S11 sweep in Touchstone format (.s1p, or .s2p of which only S11 is read), e.g. exported from a NanoVNA. The file is read in your browser and is not sent to the server.
No file loaded.
Quarter-wave transformer
Phasing lines (antennas in parallel)
Lengths use the entered VF: replace it with a measured VF (“Measured VF” tab) for a critical section.
Limits published by the manufacturer for the selected cable, at the calculator frequency. They are never derived from attenuation.
A lossy line at physical temperature T adds noise: F = 1 + (L − 1)·T/290 K, then the Friis formula with the receiver.
Lengths of the selected cable that meet a loss budget, using the calculator conditions (SWR, connectors, additional losses).
dBd = dBi − 2.15 dB (reference half-wave dipole). dBW = dBm − 30.
Datasheet of the selected cable
Methodology, assumptions and limits
Data
Every value comes from the cited manufacturer datasheet, with URL and verification date. A missing value is shown as “not documented”. Dimensions published in inches are converted (1 in = 25.4 mm); dB/100 ft → dB/100 m: divide by 0.3048.
Attenuation at any frequency
Datasheet point: documented value. Between two points: linear interpolation on a log-log scale (local power law A ∝ fk), flagged as an estimate. Out of range: manufacturer formula k1·√f + k2·f if the datasheet publishes one (Times Microwave), otherwise no value, unless extrapolation is explicitly allowed in expert mode.
Mismatched line
For a matched loss A (dB), a = 10−A/10, ρ = |ΓL| = (SWR − 1)/(SWR + 1): Pload/Pin = a(1 − ρ²)/(1 − ρ²a²); |Γin| = ρ·a. These relations are exact for a uniform line with real Z0 and do not depend on phase. The “SWR & line” tab solves the telegrapher's equations for a complex load and any SWR meter reference.
Measured cable and measured VF (v1.1)
Measurement correction: k = measured loss / datasheet loss at the same frequency and length; the datasheet curve is multiplied by k (proportional assumption, flagged). With the far end open or shorted, reflection is total: one-way loss = RL/2. VF by resonance: open end, minima at L = (2n−1)·λc/4; shorted end, minima at L = n·λc/2.
Limits
- Z0 assumed real (approximation: at low HF frequencies the Z0 of a lossy cable becomes slightly complex).
- “Typical” or “nominal” attenuation per manufacturer; production tolerances are not included.
- Power ratings depend on the published conditions (ambient temperature, SWR 1, altitude); SWR and temperature reduce the power actually allowed.
- Connectors and components are treated as matched losses in series with the cable.
- No temperature effect on attenuation is modelled: no coefficient is documented in the included datasheets.